An investigative case study at local hospital into the current reliability of blood pressure sphygmomanometers

Faria, Vinícius Naves Rezende; Mendonça, Gustavo; Souza, Daniel Baldoino de; Pereira, Adriano Alves; Arencibia, Rosenda Valdés; Milagre, Selma Terezinha

Downloads: 0
Views: 862

Abstract

Introduction: Arterial Blood Pressure is a significant indicator of the current health condition of an individual. The correct detection of hypertension is essential, where this health problem is considered as one of the greatest health risks factors that affect the heart and circulatory system. This paper presents the importance of the application of metrological criteria for the diagnosis of hypertension using a sphygmomanometer aneroid. Methods: 72 mechanical aneroid sphygmomanometers were calibrated using a standard manometer and the indication error, hysteresis, air leakage and rapid exhaust were determined; readings of these sphygmomanometers were compared to a properly calibrated and adjusted aneroid sphygmomanometer to carry out pressure measurements as those made during the hypertension diagnosis; the uncertainty of measurement associated with the sphygmomanometers calibration, and pressure values was assessed according to the recommendations of the Guide to the Expression of Uncertainty in Measurement, defined by the Joint Committee for Guides in Metrology. Results: The results obtained have shown that about 61% of the evaluated aneroid sphygmomanometers did not meet the specifications. The variable that most contributed to the final calibration uncertainty was the hysteresis of the standard manometer, with 53% of contribution, followed by the sphygmomanometer resolution with 27%. Conclusion: The periodic verifications are essential to evaluate the performance of these devices. It was shown that uncertainty of measurement influences the final diagnosis of hypertension and the application of metrological criteria can increase the reliability of the final diagnosis.    

Keywords

Aneroid sphygmomanometers, Calibration, Uncertainty.

References

Ali S, Rouse A. Practice audits: reliability of sphygmomanometers and blood pressure recording bias. Journal of Human Hypertension. 2002; 16(5):359-61. PMid:12082498. http://dx.doi.org/10.1038/sj.jhh.1001384. 

Bailey RH, Knaus VL, Bauer JH. Aneroid sphygmomanometers: an assessment of accuracy at a university hospital and clinics. Archives of Internal Medicine. 1991; 151(7):1409-12. PMid:2064493. http://dx.doi.org/10.1001/archinte.1991.00400070157022. 

Brasil. Ministério do Desenvolvimento, Indústria e Comércio Exterior. Instituto Nacional de Metrologia, Qualidade e Tecnologia. Portaria Inmetro nº 153, de 12 de agosto de 2005. Diário Oficial da República Federativa do Brasil, Brasília, 2005 [cited 2015 Apr 29]. Available from: http://www.inmetro.gov.br/rtac/pdf/RTAC000966.pdf. 

Hussain A, Cox JG. An audit of the use of sphygmomanometers. The British Journal of Clinical Practice. 1996; 50(3):136-7. PMid:8733331. 

Instituto Nacional de Metrologia, Qualidade e Tecnologia. NIE-DIMEL-006: procedimentos de verificação e inspeção de esfigmomanômetros mecânicos [internet]. 2014 [cited 2015 Apr 29]. Available from: http://www.inmetro.gov.br/metlegal/docDisponiveis.asp. 

International Organization for Standardization. ISO/IEC 17025:2005. General requirements for the competence of testing and calibration laboratories. Geneva: ISO; 2005. 28 p. 

International Organization of Legal Metrology. R16-1:2002: non-invasive mechanical sphygmomanometers. Paris: OIML; 2002. 

Introcaso L. História da pressão arterial: 100 anos do esfigmomanômetro. Arquivos Brasileiros de Cardiologia. 1996; 67(5):305-11. PMid:9239863. 

James PA, Oparil S, Carter BL, Cushman WC, Dennison-Himmelfarb C, Handler J, Lackland DT, LeFevre ML, MacKenzie TD, Ogedegbe O, Smith SC Jr, Svetkey LP, Taler SJ, Townsend RR, Wright JT Jr, Narva AS, Ortiz E. Evidence-based guideline for the management of high blood pressure in adults: report from the panel members appointed to the Eighth Joint National Committee (JNC 8). Journal of the American Medical Association. 2014; 311(5):507-20. PMid:24352797. http://dx.doi.org/10.1001/jama.2013.284427. 

Joint Committee for Guides in Metrology. JCGM 100: guide to the expression of uncertainty in measurement. Geneva: JCGM; 2008. 131 p. 

Lessa V, Bernardo S, Garrido FSRG, Garrido RG. Manutenção e calibração de esfigmomanômetros: possíveis impactos na medição da pressão arterial. Colloquium Vitae. 2014; 6(3):91-8. http://dx.doi.org/10.5747/cv.2014.v06.n3.v116. 

Mendonça GS, Souza DB, Milagre ST. Controle de qualidade dos esfigmomanômetros aneróides de um hospital universitário de grande porte. In: Proceedings of the 23º Congresso Brasileiro de Engenharia Biomédica; 2012 Oct 1-5; Porto de Galinhas, Brazil. Rio de Janeiro: Editora da SBEB; 2012. p. 570-4. 

Mendonça GS. Levantamento do perfil dos esfigmomanômetros aneróides do Hospital de Clínicas da Universidade Federal de Uberlândia por meio de avaliação eventual [monograph]. Uberlândia: Universidade Federal de Uberlândia; 2012. 82 p. 

Minor DS, Butler KR Jr, Artman KL, Adair C, Wang W, McNair V, Wofford MR, Griswold M. Evaluation of blood pressure measurement and agreement in an Academic Health Sciences Center. Journal of Clinical Hypertension. 2012; 14(4):222-7. PMid:22458743. http://dx.doi.org/10.1111/j.1751-7176.2012.00599.x. 

Mion D Jr, Pierin A, Lessa I, Nobre F. Aparelhos, técnicas de medida da pressão arterial e critérios de hipertensão adotados por médicos brasileiros. Estudo exploratório. Arquivos Brasileiros de Cardiologia. 2002; 79(6):593-6. PMid:12532243. 

Monteiro EC, Lessa ML. A metrologia na área de saúde: garantia da segurança e da qualidade dos equipamentos eletromédicos. Engevista. 2005; 7(2):51-60. 

Moore TA, Sorokin AV, Hirst C, Thornton-Thompson S, Thompson PD. The accuracy of aneroid sphygmomanometers in the ambulatory setting. Journal of Preventive Cardiology. 2008; 11(2):90-4. PMid:18401236. http://dx.doi.org/10.1111/j.1751-7141.2008.06600.x. 

Moreira LF. The Archives and the publication of its first impact factor. Arquivos Brasileiros de Cardiologia. 2010; 95(1):1-51. PMid:20694399. 

National Heart Foundation of Australia. Guideline for the diagnosis and management of hypertension in adults – 2016. Melbourne: National Heart Foundation of Australia; 2016. 

Pater C. Beyond the evidence of the new hypertension guidelines. Blood pressure measurement: is it good enough for accurate diagnosis of hypertension? Time might be in, for a paradigm shift (I). Current Controlled Trials in Cardiovascular Medicine. 2005; 6(1):6. PMid:15813975. http://dx.doi.org/10.1186/1468-6708-6-6. 

Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves JW, Hill MN, Jones DH, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans: an AHA scientific statement from the Council on High Blood Pressure Research Professional and Public Education Subcommittee. Journal of Clinical Hypertension. 2005; 7(2):102-9. PMid:15722655. http://dx.doi.org/10.1111/j.1524-6175.2005.04377.x. 

Pickering TG, Ogedegbe G. Principles and techniques of blood pressure measurement. Cardiology Clinics. 2010; 28(4):571-86. PMid:20937442. http://dx.doi.org/10.1016/j.ccl.2010.07.006. 

Piper MA, Evans CV, Burda BU, Margolis KL, O’Connor E, Whitlock EP. Diagnostic and predictive accuracy of blood pressure screening methods with consideration of rescreening intervals: a systematic review for the U.S. Preventive Services Task Force. Annals of Internal Medicine. 2015; 162(3):192-204. PMid:25531400. http://dx.doi.org/10.7326/M14-1539. 

Powers BJ, Olsen MK, Smith VA, Woolson RF, Bosworth HB, Oddone EZ. Measuring blood pressure for decision making and quality reporting: where and how many measures? Annals of Internal Medicine. 2011; 154(12):781-8, W-289-90. PMid:21690592. http://dx.doi.org/10.7326/0003-4819-154-12-201106210-00005. 

Rouse A, Marshall T. The extent and implications of sphygmomanometer calibration error in primary care. Journal of Human Hypertension. 2001; 15(9):587-91. PMid:11550103. http://dx.doi.org/10.1038/sj.jhh.1001241. 

Tolonen H, Koponen P, Naska A, Männistö S, Broda G, Palosaari T, Kuulasmaa K. Challenges in standardization of blood pressure measurement at the population level. BMC Medical Research Methodology. 2015; 15(1):33. PMid:25880766. http://dx.doi.org/10.1186/s12874-015-0020-3. 

Turner MJ, Irwig L, Bune AJ, Kam PC, Baker AB. Lack of sphygmomanometer calibration causes over- and under-detection of hypertension: a computer simulation study. Journal of Hypertension. 2006; 24(10):1931-8. PMid:16957551. http://dx.doi.org/10.1097/01.hjh.0000244940.11675.82. 

Turner MJ, Kam PC, Baker AB. Metrology in Medicine. Proceedings of the 5th Biennial Conference of the Metrology Society of Australia [internet]. 2004 March [cited 2016 Aug 17]; 1(1):[about 6 p]. Available from: https://www.researchgate.net/profile/Stephan_Mieke/publication/229650616_Metrology_in_Medicine/links/558bdf5708aee43bf6ad04ad.pdf. 

Weckenmann A, Knauer M, Killmaier T. Uncertainty of coordinate measurements on sheet-metal parts in the automotive industry. Journal of Materials Processing Technology. 2001; 115(1):9-13. http://dx.doi.org/10.1016/S0924-0136(01)00758-0. 

World Health Organization. Guidelines for the management of hypertension. Journal of Hypertension. 1999; 17(2):151-83. PMid:10067786. 

Yang Q, Cogswell ME, Flanders WD, Hong Y, Zhang Z, Loustalot F, Gillespie C, Merritt R, Hu FB. Trends in cardiovascular health metrics and associations with all-cause and CVD mortality among US adults. Journal of the American Medical Association. 2012; 307(12):1273-83. PMid:22427615. http://dx.doi.org/10.1001/jama.2012.339.

59e9e7f50e882596729aaad6 rbejournal Articles
Links & Downloads

Res. Biomed. Eng.

Share this page
Page Sections