Research on Biomedical Engineering
http://www.rbejournal.periodikos.com.br/article/5889fb8e5d01231a018b46a7
Research on Biomedical Engineering
Original Article

MEDICIÓN DE LA PRESIÓN ARTERIAL UTILIZANDO EL RETARDO EN EL PULSO DISTAL

ARTERIAL PRESSURE MEASUREMENT USING THE DISTAL PULSE DELAY

Infante-Vázquez, O.; Sanches, T.G.; Martínez, M. R.; Florez, C.P.; Pastelín, H.G.; Sánches, M.M.

Downloads: 0
Views: 991

Resumen

Durante la compresion arterial en la esfigmomanometría (EM) auscultatnria (EMA) ocurre un retardo en la aparición dei pulso sanguíneo distai (PSD), lo que se expresa en <;; iü.~eivalo Q-pP (Onda Q dei ECG - pie de ascenso dei PSD). Para determinar este lapso, hemos desarrollado un equipo que automáticamente mide y registra la variabilidad de los intervalos Q-Q y Q-pP, aplicándolo a la medición de la presión arterial (PA) sistólica (PS) y diastólica (PD). EI aparato toma la derivación aVR dei ECG, eI PSD de un dedo de la mano (tomado de la luz reflejada desde dos fuentes de diferente longitud de onda) y la presión dei brazal durante la EM. Cada serral se capturó a 250 muestras por segundo durante 70 a 100 sego Se compararon la EMA y nuestro nuevo método de obtención de la PA (NMEM) en 262 casos (129 normotensos y 133 hipertensos). Para las mediciones se aplicaron las regias estándar de la EM y los siguientes criterios: las clásicas primera y quinta fase de Korotkoff para la PS y la PD respectivamente en la EMA, y para el NMEM el primer PSD para la PS y la desaparición dei retardo en el Q-pP para la PD. La PS medida por EMA o por NMEM correlacionan significativamente (r = 0.94, p> 0.001), pero esta relación es menor en la PD (r = 0.80, P < 0.005). EI NMEM es un procedimiento fácil de realizar que mide objetivamente la PA Yque puede tener interesantes usos clínicos.

Palabras clave

Esfigmomanometría, Medición de la Presión Arterial, Hipertensión

Abstract

A delay in the appearance of distaI arterial pulse (dP), expressed in QdP interval (Q ECG wave-distal arterial pulse onset), occurs during compression phase of systolic (SBP) and diastolic (DBP) blood pressure determination (BPD) by sphygmomanometry (SMM). We developed a digital system that automaticalIy measures and records pulse to pulse variability of Q-Q and Q-dP intervals, and we applied it in arterial pressure measurement. The apparatus takes 3 signals: aVR ECG lead, finger blood pulse (reflected from two wave length-light) and sphygmomanometer cuff pressure (SCP). AlI signals were taken at 250 samples/second in 70 to 100 seconds. Auscultatory (AM) and a new sphygmographic methods (NSM) of BPD were compared in 262 cases (129 with normal pressure and 133 with essential hypertension). We applied the standard rules of SMM and the folIowing SBP and DBP criteria: classical KI-K5 respectively in AM, and for NSM: SCP measured at first dP during early cuff deflation recorded as SBP index, and disappearance of Q-dP delay (obtained during late cuff deflation) as a DBP indexo SBP measured by AM or by NSM significant correlates (r = 0.94, P < 0.001) but this relationship is lower in DBP (r = 0.80, P < 0.01). NSM is a non-invasive procedure, ease to perform, which objectively measures blood pressure and may have interesting clinicaI applications.

Keywords

Blood Flow Velocity, Arterial Pressure Measurement, Hypertension